Product Features
Full length barriers between poles included
Technical Specifications of NSN
Body Style:
Multipole-multiple actuator type
Mounting Slot Width:
0.164 inches
Body Length:
Between 4.740 inches and 4.760 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 3.537 inches and 3.557 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 1.016 inches and 1.036 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.740 inches and 2.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.016 inches and 1.036 inches
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.209 inches and 0.229 inches
Mounting Surface To Terminal End Distance:
Between 3.475 inches and 3.495 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
10 threaded hole and 5 slot
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac first location
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes dc fifth location
Maximum Continuous Load Current Rating Per Pole:
5.0 amperes dc fourth location
Operating Voltage Type And Rating Per Pole In Volts:
140.0 dc fifth location
Operating Voltage Type And Rating Per Pole In Volts:
140.0 dc fourth location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac first location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 dc fifth location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
5000.0 dc fourth location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Auxiliary Trip Coil Voltage Type And Rating In Volts:
25.0 dc first location
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
5 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, three, four, and five linked
Internal Trip Release Configuration:
Series trip fifth location
Internal Trip Release Configuration:
Series trip fourth location
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Internal Trip Release Configuration:
Series/relay trip first location
Thread Size:
0.138 inches
Trip Release Duty Cycle:
Continuous first location
Trip Delay Time In Seconds Per Rated Continuous Current:
20.000 at 200 pct second location and 100.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
20.000 at 200 pct first location and 100.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
20.000 at 200 pct third location and 100.000 at 200 pct third location
Trip Delay Time In Seconds Per Rated Continuous Current:
25.000 at 200 pct fifth location and 95.000 at 200 pct fifth location
Trip Delay Time In Seconds Per Rated Continuous Current:
25.000 at 200 pct fourth location and 95.000 at 200 pct fourth location
Inclosure Protection Type For Which Designed:
Vibration resistant and shock resistant and moisture resistant and salt spray proof
Frequency In Hertz:
60.0 first location
Frequency In Hertz:
60.0 second location
Frequency In Hertz:
60.0 third location
Thread Series Designator:
Unc
Terminal Type And Quantity:
12 threaded stud
Item Name:
Breaker,individual
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC