Detail Specifications
Body Style:
Multipole-multiple actuator type
Body Length:
2.500 inches
Center To Center Distance Between Terminals Parallel To Length:
1.938 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.062 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
Fragility Factor:
Moderately rugged
Boss Height:
0.140 inches
Mounting Surface To Terminal End Distance:
2.611 inches
Arc Quenching Method:
Air
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
1.0 amperes dc first location
Maximum Continuous Load Current Rating Per Pole:
2.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
2.0 amperes ac third location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac third location
Operating Voltage Type And Rating Per Pole In Volts:
50.0 dc first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 dc first location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
5.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
12.500 at 200 pct third location
Trip Delay Time In Seconds Per Rated Continuous Current:
12.500 at 200 pct second location
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Frequency In Hertz:
60.0 second location
Frequency In Hertz:
60.0 third location
Test Data Document:
01714-g383753 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 threaded stud
Item Name:
Motor Circuit Protector