Multipole-single actuator type body style, 0.375 inches bushing length, 1.495 inches body length, 1.872 inches body width, metal case material.
Detail Specifications
Body Style:
Multipole-single actuator type
Bushing Length:
0.375 inches
Body Length:
1.495 inches
Center To Center Distance Between Terminals Parallel To Length:
0.875 inches
Center To Center Distance Between Terminals Parallel To Width:
0.625 inches
Nonturn Device Location:
At 3 oclock and at 9 oclock
Nonturn Device Radius:
Between 0.620 inches and 0.630 inches
Nonturn Device Diameter:
0.138 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
1.678 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac first location and 50.0 milliamperes dc first location
Maximum Continuous Load Current Rating Per Pole:
15.0 amperes ac second location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac first location and 10.0 dc first location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
300.0 ac third location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
300.0 ac first location and 500.0 dc first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
300.0 ac second location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Instantaneous first location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
1.000 at 200 pct second location and 4.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
1.000 at 200 pct third location and 4.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
Fungus resistant and hermetically sealed and moisture resistant
Frequency In Hertz:
60.0 all locations
Unpackaged Unit Weight:
4.500 ounces
Precious Material And Location:
Contact surfaces silver
Precious Material:
Silver
Thread Series Designator:
Unef
Terminal Type And Quantity:
6 wire hook
Item Name:
Breaker,input Mains
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC