Product Technical Spec.
Body Style:
Multipole-multiple actuator type
Body Length:
2.000 inches
Center To Center Distance Between Terminals Parallel To Length:
1.560 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
1.660 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.750 inches
Boss Height:
0.130 inches
Mounting Surface To Terminal End Distance:
1.950 inches
Mounting Facility Type And Quantity:
4 clip
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac first location and 10.0 amperes dc first location
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac second location and 10.0 amperes dc second location
Operating Voltage Type And Rating Per Pole In Volts:
115.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac first location and 1000.0 dc first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac second location and 1000.0 dc second location
Circuit Protection Type:
Overcurrent first location
Circuit Protection Type:
Overcurrent second location
Trip Release Method:
Magnetic first location
Trip Release Method:
Magnetic second location
Auxiliary Trip Coil Voltage Type And Rating In Volts:
115.0 ac second location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 first location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 second location
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
2 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
Internal Trip Release Configuration:
Series trip first location
Internal Trip Release Configuration:
Series trip w/remote trip feature second location
Trip Release Duty Cycle:
Continuous second location
Trip Delay Time In Seconds Per Rated Continuous Current:
6.000 at 150 pct first location and 70.000 at 150 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
0.400 at 150 pct second location and 6.000 at 150 pct second location
Frequency In Hertz:
50.0 first location or 60.0 first location or 400.0 first location
Frequency In Hertz:
50.0 second location or 60.0 second location or 400.0 second location
Terminal Type And Quantity:
5 knife blade
Item Name:
Thermal Magnetic Trip Breaker
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC