Use in appliances/elect. Equip. Where branch circuit breaker protection is provided or not required; for use with oem panels; terminal type: box lug, 2; wire size: no. 14 to no. 4 awg (cu); trip curve: c curve - magnetic operates between 7 to 10 times
No other part numbers with same form, fit, and function found.
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts
NSN 6105-00-598-1614
NSN 5910-01-468-6632
NSN 6105-01-501-4458
NSN 5895-01-483-1946
NSN 5990-00-734-7285
NSN 4140-01-368-5215
NSN 5990-00-589-5045
NSN 5930-00-801-7680
NSN 5975-01-451-4799
NSN 5920-01-247-4601
NSN 5960-01-248-4743
NSN 6610-00-935-7131
Last Updated: 11/24/2024