Detail Specifications
Body Style:
Multipole-multiple actuator type
Bushing Length:
Between 0.099 inches and 0.161 inches
Body Length:
Between 2.219 inches and 2.281 inches
Body Width:
Between 1.969 inches and 2.031 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.529 inches and 1.591 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 1.629 inches and 1.691 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 0.719 inches and 0.781 inches
Switch Contact Arrangement:
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 1.629 inches and 1.691 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
2.032 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
240.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
1000.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
150.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
3 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At each pole
External Actuator Linkage Arrangement:
One, two, and three linked
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
2.100 at 200 pct all locations and 20.000 at 200 pct all locations
Inclosure Protection Type For Which Designed:
Fungus resistant
Switch Terminal Type:
Tab, solder lug
Switch Current Rating And Type In Amps:
5.0 ac and 5.0 dc
Switch Voltage Rating And Type In Volts:
240.0 ac and 50.0 dc
Frequency In Hertz:
400.0 all locations
Test Data Document:
81349-mil-c-55629 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator:
Unc
Terminal Type And Quantity:
6 tab w/screw
Specification Data:
81349-mil-c-55629/12 government specification
Item Name:
Tri-break Fused Circuit Breaker
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC