#SMA717609 Line Protective Switch plastic case material

SMA717609

Circuit Breaker

NSN 5925-00-124-9613

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
N/A
UOM:
1 EA
NIIN:
001249613
Description

+0.1177/+0.1214 inches thread pitch diameters, single pole type body style, 3.709 inches body length, 0.980 inches body width, plastic case material.

Detail Specifications

Thread Pitch Diameters:
+0.1177/+0.1214 inches
Thread Pitch Diameters:
+0.1177 to 0.1214 inches
Body Style:
Single pole type
Body Length:
Between 3.709 inches and 3.729 inches
Body Width:
Between 0.980 inches and 1.000 inches
Case Material:
Plastic
Center To Center Distance Between Terminals Parallel To Length:
Between 3.053 inches and 3.073 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.740 inches and 2.760 inches
Switch Contact Arrangement:
Single pole, double throw
Fragility Factor:
Moderately rugged
Boss Height:
Between 0.146 inches and 0.166 inches
Mounting Surface To Terminal End Distance:
Between 3.167 inches and 3.259 inches
Pole Quantity:
1
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
2 threaded hole
Storage Type:
General purpose warehouse
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
10.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts:
125.0 ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 ac single location
Circuit Protection Type:
Overcurrent single location
Trip Release Method:
Magnetic single location
Trip Release Characteristic:
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 single location
Reset Method:
Manual
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole one
Auxiliary Switch Function And Quantity:
1 alarm
Internal Trip Release Configuration:
Series trip single location
Thread Size:
0.138 inches
Switch Location And Position Designation:
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current:
35.000 at 200 pct single location and 105.000 at 200 pct single location
Inclosure Protection Type For Which Designed:
Fungus resistant and moisture resistant
Switch Terminal Type:
Pin
Switch Current Rating And Type In Amps:
5.0 ac
Switch Voltage Rating And Type In Volts:
125.0 ac
Frequency In Hertz:
60.0 single location
Thread Series Designator:
Unc
Terminal Type And Quantity:
2 threaded stud
NSN:
5925-00-124-9613
Item Name:
Line Protective Switch
Cage Code:
80063

Manufacturer Part Numbers

No other part numbers with same form, fit, and function found.

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number sma717609 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Circuit Breakers
--------- Circuit Breakers
------------ P/N SMA717609

New Products Recently updated in circuit breakers

  • 27-10388-1 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 1536-007-10 circuit breaker
    NSN 5925-00-166-3440

    Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height

  • 314C920G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • KA3150 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • 504C336G21 circuit breaker
    NSN 5925-00-165-8693

    3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts

  • BAB1015 circuit breaker
    NSN 5925-00-165-8694

    1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts


Best-Selling Products A collection of our most popular products