Rocker actuator attached to circuit breaker handle
Technical Specifications of NSN
Body Style:
Multipole-multiple actuator type
Bushing Length:
Between 0.235 inches and 0.265 inches
Body Length:
Between 1.985 inches and 2.015 inches
Body Width:
Between 2.260 inches and 2.270 inches
Center To Center Distance Between Terminals Parallel To Length:
Between 1.515 inches and 1.545 inches
Center To Center Distance Between Terminals Parallel To Width:
Between 0.735 inches and 0.765 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 1.647 inches and 1.677 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.735 inches and 0.765 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
2.390 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
6 threaded hole
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
30.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
3500.0 ac all locations
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Auxiliary Trip Coil Voltage Type And Rating In Volts:
250.0 ac first location
Trip Release Characteristic:
Instantaneous first location
Trip Release Characteristic:
Time delay second location
Trip Release Characteristic:
Time delay third location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
125.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Internal Trip Release Configuration:
Series trip second location
Internal Trip Release Configuration:
Series trip third location
Internal Trip Release Configuration:
Series/relay trip first location
Thread Size:
0.138 inches
Trip Release Duty Cycle:
Continuous first location
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct second location and 20.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
2.000 at 200 pct third location and 20.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
Corrosion resistant and moisture resistant and shock resistant and vibration resistant
Frequency In Hertz:
50.0 all locations or 60.0 all locations
Thread Series Designator:
Unc
Terminal Type And Quantity:
8 quick disconnect, male
Item Name:
Switch,overload
Other Related Parts