Ground fault circuit interrupter; end item: part no. Fg2200; used in support with 6540-01-604-9603, ophthalmic lens fabrication system; line power: 115 v, 1725 watts, 15 a, 50/60 hz, single phase
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
Multipole-single actuator type body style, 0.250 inches bushing length, 1.312 inches body length, 2.140 inches body width, 2.156 inches body height
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
3 pole quantity, 150.0 amperes ac all locations maximum continuous load current rating per pole, 600.0 ac all locations operating voltage type and rating per pole in volts
1 pole quantity, 15.0 amperes ac single location maximum continuous load current rating per pole, 240.0 ac single location operating voltage type and rating per pole in volts
NSN 6105-00-285-2774
NSN 5950-01-279-9041
NSN 5998-00-739-7994
NSN 5950-01-434-5105
NSN 5835-01-208-8800
NSN 6130-01-122-7112
NSN 6650-01-379-6244
NSN 5999-01-590-9555
NSN 5915-00-045-9071
NSN 5990-01-100-1840
NSN 5920-01-189-9248
NSN 6610-01-302-6347