Detail Specifications
Reliability Indicator:
Not establishednot establishednot established
Center To Center Distance Between Mounting Facilities Parallel To Length:
1.688 inches single mounting facility single center group1.688 inches single mounting facility single center group1.688 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width:
1.219 inches single mounting facility single center group1.219 inches single mounting facility single center group1.219 inches single mounting facility single center group
Mounting Hole Diameter:
0.156 inches single group0.156 inches single group0.156 inches single group
Frequency Rating:
330.0 hertz single component and 330.0 hertz single component and 330.0 hertz single component and 1.76 kilohertz single component1.76 kilohertz single component1.76 kilohertz single component
Input-output Phase Relationship:
Single phase to single phase single componentsingle phase to single phase single componentsingle phase to single phase single component
Winding Shielding Method:
Internal shield brought out to terminal single componentinternal shield brought out to terminal single componentinternal shield brought out to terminal single component
Body Length:
2.312 inches 2.312 inches 2.312 inches
Body Width:
2.125 inches 2.125 inches 2.125 inches
Body Height:
2.250 inches 2.250 inches 2.250 inches
Maximum Operating Temp:
71.0 degrees celsius71.0 degrees celsius71.0 degrees celsius
Inclosure Type:
Fully enclosedfully enclosedfully enclosed
Mounting Facility Quantity:
4 single group4 single group4 single group
Mounting Method:
Flange single group and flange single group and flange single group and unthreaded hole single groupunthreaded hole single groupunthreaded hole single group
Winding Function And Quantity:
1 primary single component and 1 primary single component and 1 primary single component and 1 secondary single component1 secondary single component1 secondary single component
Winding Operating Current:
12.0 milliamperes ac single component single secondary
Winding Operating Voltage:
115.00 ac volts single component single primary
Winding Operating Voltage:
115.00 ac volts single component single primary640.00 ac volts single component single secondary and 660.00 ac volts single component single secondary and 680.00 ac volts single component single secondary
Terminal Type And Quantity:
7 tab, solder lug
Item Name:
Transformer,power,distribution
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC