Additional electrical requirements include input voltage normal limits 108/187 to 118/204.4 vac 3 phase; ambient temp range -55 degrees to +71 degrees centigrade; operating altitude is sea level to 65, 000 ft; length5.940 in; 3.750 in. W; transformer is impregnated with dc-997 silicone varnish
4.540 inches overall length, 2.987 inches overall height, 3.802 inches overall width, open inclosure type, 6 single group mounting facility quantity
4.540 inches overall length, 2.987 inches overall height, 3.802 inches overall width, open inclosure type, 6 single group mounting facility quantity
0.410 inches single group mounting slot width, 60.0 hertz single component frequency rating, single phase to single phase single component input-output phase relationship
1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length
1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length
1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length
NSN 6130-01-375-0874
NSN 5950-01-308-9327
NSN 5925-01-406-5626
NSN 5935-01-529-7337
NSN 5910-00-080-9843
NSN 5960-01-407-1350
NSN 6150-01-166-4577
NSN 5960-00-945-1107
NSN 6150-00-624-8718
NSN 5915-00-399-7803
NSN 6130-00-196-5292
NSN 6685-01-634-0611