Input 235 volts peak, 420 amp peak, 0.003 ohms dcr , 535 v wkg; output 6100 volts peak, 19.2 amp peak, 0.500 ohms dcr , 6100 v wkg for windings 3-5 output for windings 6-7 are 23 volts peak, 1a rms, 535 v wkg, 0.05 ohms, altitude 10000 feet, ambient temperature 65 degrees c, unit designed to operate in transformer oil
No other part numbers with same form, fit, and function found.
4.540 inches overall length, 2.987 inches overall height, 3.802 inches overall width, open inclosure type, 6 single group mounting facility quantity
4.540 inches overall length, 2.987 inches overall height, 3.802 inches overall width, open inclosure type, 6 single group mounting facility quantity
0.410 inches single group mounting slot width, 60.0 hertz single component frequency rating, single phase to single phase single component input-output phase relationship
1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length
1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length
1.750 inches single mounting facility single center group center to center distance between mounting facilities parallel to length
NSN 5915-00-304-8195
NSN 6650-00-488-8898
NSN 5915-01-264-5380
NSN 5835-00-466-8544
NSN 5925-01-185-9897
NSN 5905-00-741-3431
NSN 5960-01-391-8860
NSN 6610-01-310-0553
NSN 5965-00-324-2428
NSN 6610-01-013-8922
NSN 5855-01-380-6186
NSN 5905-01-029-3698
Last Updated: 07/18/2025