Technical Specifications of NSN
Reliability Indicator:
Not established
Center To Center Distance Between Mounting Facilities Parallel To Length:
5.750 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width:
3.875 inches single mounting facility single center group
Frequency Rating:
50.0 hertz single component or 60.0 hertz single component
Frequency Rating:
50.0 hertz or 60.0 hertz single component
Input-output Phase Relationship:
Single phase to single phase single component
Body Length:
8.250 inches
Body Height:
7.375 inches
Mounting Facility Quantity:
4 single group
Mounting Method:
Flange single group and unthreaded hole single group
Mounting Method:
Flange and unthreaded hole single group
Winding Function And Quantity:
1 primary single component and 1 secondary single component
Winding Function And Quantity:
1 primary and 1 secondary single component
Winding Operating Current:
1.2 amperes ac single component single secondary
Winding Operating Voltage:
16.25 ac pounds per hour wet single component single secondary and 32.50 ac pounds per hour wet single component single secondary and 177.00 ac pounds per hour wet single component single secondary and 180.25 ac pounds per hour wet single component single secondary and 183.50 ac pounds per hour wet single component single secondary and 186.25 ac pounds per hour wet single component single secondary and 190.00 ac pounds per hour wet single component single secondary
Winding Operating Voltage:
70.00 ac pounds per hour wet single component single primary and 85.00 ac pounds per hour wet single component single primary and 95.00 ac pounds per hour wet single component single primary and 105.00 ac pounds per hour wet single component single primary and 115.00 ac pounds per hour wet single component single primary and 125.00 ac pounds per hour wet single component single primary and 190.00 ac pounds per hour wet single component single primary and 210.00 ac pounds per hour wet single component single primary and 230.00 ac pounds per hour wet single component single primary and 250.00 ac pounds per hour wet single component single primary
Winding Operating Voltage:
16.25 ac volts and 32.50 ac volts and 177.00 ac volts and 180.25 ac volts and 183.50 ac volts and 186.25 ac volts and 190.00 ac volts single component single secondary
Winding Operating Voltage:
70.00 ac volts and 85.00 ac volts and 95.00 ac volts and 105.00 ac volts and 115.00 ac volts and 125.00 ac volts and 190.00 ac volts and 210.00 ac volts and 230.00 ac volts and 250.00 ac volts single component single primary
Terminal Type And Quantity:
19 tab, solder lug
Item Name:
Transformer,power,bell Ringing
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC