Product Features
E.S.D. Critical unit; also this unit has red edge lighting
Technical Specifications of NSN
Case Material:
Aluminum alloy
Maximum Voltage Rating In Volts:
28.0 dc
End Application:
Md-1035b/a
Maximum Wattage Rating In Watts:
35.0
Terminal Type And Quantity:
1 jack
Maximumlength:
6.500 inches
Maximumwidth:
5.750 inches
Maximumheight:
6.750 inches
Criticality Code Justification:
Feat
Functional Description:
Provides operator interface for control and operational programming of modem, telegraph md-1035b/a; provides display of predetermined menus for operator to select modes of operation and specific operational parameters for modem and associated radio then enter modes and parameters selected into program for the microprocessor which controls the associated communications terminal; allows operator to initiate built-in tests; provides freq and time transfer between modem and hhm
Supplementary Features:
Interface w/hand held module (hhm) provides time and freq transfer to or from the modem; provides interface to external audible eam alarm and activates alarm when when alarm data is received from modem; power obtained from dual modem and passes through the modem circuit breaker; no provisions for internal battery
Item Name:
Remote Command Unit
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC