Detail Specifications
Overall Length:
13.560 inches
Overall Height:
3.940 inches
Overall Width:
4.940 inches
Average Life Measurement:
Not rated
End Application:
An/fps-8 (v)
Basic Shape Style:
Rectangular or square
Installation Design:
Rack
Circuit Construction Type:
Solid state
Frequency Per Channel:
1.0 megahertz operating channel
Impedance Rating Per Channel:
90.000 ohms output channel
Pulse Duration Per Channel:
2.000 microseconds output channel
Polarity Per Channel:
Positive output channel
Pulse Repetition Rate Per Channel:
360.000 pulses per second operating channel
Pulse Peak Amplitude Per Channel:
25.000 volts output channel
Signal Data Type Per Channel:
Output channel pulse
Output Wave Shape:
Square
Operating Ac Frequency In Hertz:
60.0 single voltage
External Dc Operating Voltage In Volts:
120.0 2nd voltage
External Dc Operating Voltage In Volts:
250.0 3rd voltage
External Dc Operating Voltage In Volts:
-150.0 1st voltage
External Ac Operating Voltage In Volts:
6.3 single voltage
Functional Description:
Provides the circuitry necessary to generate range trigger pulses which are federal to the electronic switch sa-1929/fps-8 (v)
Supplementary Features:
Output is a pulse which varies in time, 200 to 5000 usec from the input
Item Name:
Blanker,countermeasures
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC