Temp range differential-reads temp difference between 2 probes; resolution 0 to 60 degrees c 1/10th degree, resolution 0 to 400 degrees c one degree; accuracy 0.2% of full scale +/- 1 digit; readout bright red led digits 0.4 inch high, readable at 20 feet; works with any type t (copper/constantan) thermocouple; three probe inputs, switch selectable; recorder output 4 v max, linearized, drives all chart recorders; weigght 7 lbs; portable item with handle; has ultra stable dc amplifier that eliminates both calibration drift and the effect of thermocouple resistance
No other part numbers with same form, fit, and function found.
NSN 6610-01-156-0810
NSN 5895-01-566-9459
NSN 5920-01-182-0612
NSN 6130-01-367-2201
NSN 5996-01-293-0373
NSN 4140-01-515-2722
NSN 5945-01-628-4566
NSN 6685-01-319-0004
NSN 6685-01-481-3864
NSN 5910-01-646-1249
NSN 6320-00-456-0836
NSN 5996-00-138-9938
Last Updated: 06/29/2025