Digital pressure indicator; media air; pressure range 0 to 200 psia; calibration span 0 to 150 psia; operating temp limit 50 degrees f to 120 degrees f; storage temp -20 degrees f to 130 degrees f; speed of response 250 milliseconds for full scale traverse; display has factory located decimal point; pressure repeatabili type 0.005 percent full scale; accuracy 0.05 percent of calibrated range total error; zero adjust; span adjust internal; overpressure capabili type 200 percent of rated span; warmup time 2 hours total warmup time for full stability; bcd output 8421 binary coded decimal; mating 25 pind d type cable connector; pressure connection 1/4 inch npt female; mounting, unit design allows for retrofit directly into existing panel mounted support brackets as a direct replacement for ashcroft digigauge model 7580
NSN 5925-01-422-6228
NSN 5925-01-171-9421
NSN 5975-00-899-7952
NSN 5930-00-280-7777
NSN 5935-01-492-9889
NSN 6645-00-234-7223
NSN 5985-01-111-6253
NSN 6240-01-477-0012
NSN 5996-00-531-5398
NSN 5925-01-381-0559
NSN 5960-00-081-9255
NSN 5835-00-173-4456
Last Updated: 05/15/2024