Detail Specifications
Overall Length:
5.406 inches
Overall Width:
2.750 inches
Mounting Device Quantity:
2
Overall Diameter:
2.500 inches
Actuation Method:
Pressure sensing element
End Application:
Lantirn mobile shelter set
Voltage Rating:
28.0 volts input
Voltage Rating:
5.0 volts output
Measurement Range:
+0.0/+200.0 pounds pressure per square inch
Supplementary Features:
Oper. Temp. Limits minus 30.0 degf to pos. 180.0 degrees f; enclosure-stainless steel; measured fluids-any fluid compatible with hastalloy c, 303 sst., andviton 'o' ring
Item Name:
Transducer Unit,static Pressure
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC