Shall be capable of connecting toand testing movement thermo-couples; meter-movement resistance temperature detectors (rtds); servo thermo-couples ; and commercial thermo-couples type k/t/j and tf-30, case shall be no more than 20 inches long, 15 inches wide, and 15 inches high, case will have a handle attached and a lockingmechanism p rovided, weight shall be no more than 35 pounds; interface shall be providedthat will display values being measured or sourced while operating between 50 and 100 degrees farenheit, temperature calibrator shall have an on/off power switch; battery charge indicator; source/measure switch; output voltage tuning ability from 0-35volts down to .5mv of the desired output; mode select capability; ability to test single or double rtd indicators; ability to source 22.5 or 28.5 volts plus or minus .5mv; ability to simulate rtd and synchro indicator voltage ranges, will include 115/230v AC at 60hz power cable
NSN 6135-01-431-6801
NSN 6650-01-536-2526
NSN 5935-01-423-2196
NSN 6135-00-276-7625
NSN 6220-01-381-1074
NSN 5925-01-293-8349
NSN 6645-01-518-1107
NSN 5998-01-634-0604
NSN 7035-01-375-3719
NSN 5996-00-289-9847
NSN 5915-01-440-9856
NSN 5990-01-395-4194
Last Updated: 05/23/2025