Indicator case per ms33639-2; dual indicator with 2 scales pressure and temperature; temp range -50 to 150 degrees c; accuracy temp-pressure +/- 2% full scale; scale illumination per mil-l-25467 red; weight 220 gms max; glass 1/16 thick non reflective coating per mil-c-675; dial lamps ms90451-6832 5 volts, 0.060 amps 4 each; visibility angle 46 degrees min; colors: case black 37038 per fed-std-595; scale markings white 37875 per fed-std-595; scale blackground black 37038 per fed-std-595; pointer white 37875 per fed-std-595; external temp sensor res. Bulb per mil-b-7990; external pressure transmitter tru-66/a per mil-t-38230; indicator meets requirements of para 4 mil-a-6752; dielectric strength 500 v rms at 60 hz; connector mates with ms3126e12-10sy
NSN 5960-01-423-4240
NSN 5925-01-146-8745
NSN 5925-00-539-8372
NSN 6105-01-496-3073
NSN 6145-01-481-4195
NSN 5915-00-782-5026
NSN 6320-01-443-6975
NSN 6620-01-223-2441
NSN 6610-01-154-5493
NSN 5915-01-487-7703
NSN 6685-00-371-5492
NSN 5999-01-421-5739