Technical Specifications of NSN
Reference Frequency Per Function:
135.0 megahertz blank
Source Impedance Rating Per Function:
50.0 ohms blank
Load Impedance Per Function:
50.0 ohms blank
Mounting Facility Type And Quantity:
2 clamp
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 blank
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
Functional Terminal Type And Quantity:
1 connector, receptacle output 2nd function
Specified Frequencies Of Discrimination Per Function:
105.00 megahertz blank and 129.00 megahertz blank and 141.00 megahertz blank and 165.00 megahertz blank
Frequency Band Width Per Function:
129.00 megahertz blank and 141.00 megahertz blank
Discrimination At Specificationified Frequencies Per Function In Decibels:
70.0 blank and 1.0 blank and 1.0 blank and 70.0 blank
Item Name:
Band Pass Filter
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC