Technical Specifications of NSN
Overall Height:
2.910 inches
Body Length:
1.870 inches
Body Height:
1.870 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.562 inches
Reference Frequency Per Function:
50.0 7th high pass any acceptable
Reference Frequency Per Function:
428.0 single high pass any acceptable
Reference Frequency Per Function:
428.0 hertz single band pass 1st function
Reference Frequency Per Function:
50.0 hertz single low pass 2nd function
Source Impedance Rating Per Function:
1.2 kilohms single band pass
Source Impedance Rating Per Function:
1.2 kilohms single low pass
Source Impedance Rating Per Function:
1.2 kilohms single band pass 1st function
Source Impedance Rating Per Function:
1.2 kilohms single low pass 2nd function
Load Impedance Per Function:
2.4 kilohms single band pass
Load Impedance Per Function:
2.4 kilohms single low pass
Load Impedance Per Function:
2.4 kilohms single band pass 1st function
Load Impedance Per Function:
2.4 kilohms single low pass 2nd function
Input Impedance Per Function W/load:
50.0 ohms blank
Output Impedance Per Function W/source Across Input:
50.0 ohms blank
Principal Circuitry Type Per Function:
Inductance-capacitance single low pass
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance single band pass
Principal Circuitry Type Per Function:
Inductance-capacitance single low pass 2nd function
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance single band pass 1st function
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
2 threaded hole
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 single low pass
Insertion Loss At Reference Frequency Per Function In Decibels:
6.0 single band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 single low pass 2nd function
Insertion Loss At Reference Frequency Per Function In Decibels:
6.0 single band pass 1st function
Functional Terminal Type And Quantity:
1 standard tube base output 2nd function
Functional Terminal Type And Quantity:
1 wire hook ground 3rd function
Functional Terminal Type And Quantity:
2 wire hook input 1st function
Specified Frequencies Of Discrimination Per Function:
1.00 hertz single low pass and 100.00 hertz single low pass and 850.00 kilohertz single low pass and 1.70 kilohertz single low pass
Thread Size:
0.138 inches
Frequency Band Width Per Function:
1.00 hertz single low pass and 100.00 hertz single low pass
Frequency Band Width Per Function:
388.00 hertz single band pass and 468.00 hertz single band pass
Frequency Band Width Per Function:
1.00 hertz single low pass and 100.00 hertz single low pass 2nd function
Frequency Band Width Per Function:
388.00 hertz single band pass and 468.00 hertz single band pass 1st function
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 single low pass and 3.0 single low pass and 50.0 single low pass and 50.0 single low pass
Style Designator:
Rectangular terminal/terminals on one surface
Item Name:
Filter,band Pass-low Pass
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC