Product Features
Electrostatic shield brought out to terminal six
Technical Specifications of NSN
Overall Height:
3.230 inches
Body Length:
3.000 inches
Body Height:
2.950 inches
Vibration Resistance Range In Hertz:
+10.0/+500.0
Operating Tempurature Range:
-55.0/+65.0 degrees celsius
Average Life Rating In Hours:
10000.0
Reference Frequency Per Function:
1.105 single radio interference pulses per second
Reference Frequency Per Function:
1.105 single radio interference two phase to three phase
Reference Frequency Per Function:
1.105 single radio interference two phase to two phase
Source Impedance Rating Per Function:
600.0 ohms 1st band pass
Source Impedance Rating Per Function:
600.0 ohms 2nd band pass
Source Impedance Rating Per Function:
600.0 ohms 3rd band pass
Load Impedance Per Function:
600.0 ohms 1st band pass
Load Impedance Per Function:
600.0 ohms 2nd band pass
Load Impedance Per Function:
600.0 ohms 3rd band pass
Principal Circuitry Type Per Function:
Inductance-capacitance 1st band pass 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd band pass 2nd function
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd band pass 3rd function
Mounting Facility Screw Thread Series Designator:
Unc
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
2 threaded stud
Mounting Facility Type And Quantity:
4 threaded hole
Features Provided:
Electrostatic shield
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 3rd band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 2nd band pass
Functional Terminal Type And Quantity:
1 turret ground 3rd function
Functional Terminal Type And Quantity:
2 turret input 1st function
Functional Terminal Type And Quantity:
3 turret output 2nd function
Specified Frequencies Of Discrimination Per Function:
1.0625 kilohertz 1st band pass 1st function and 1.08375 kilohertz 1st band pass 1st function and 1.12625 kilohertz 1st band pass 1st function and 1.1475 kilohertz 1st band pass 1st function
Specified Frequencies Of Discrimination Per Function:
1.0625 kilohertz 2nd band pass 2nd function and 1.08375 kilohertz 2nd band pass 2nd function and 1.12625 kilohertz 2nd band pass 2nd function and 1.1475 kilohertz 2nd band pass 2nd function
Specified Frequencies Of Discrimination Per Function:
1.0625 kilohertz 3rd band pass 3rd function and 1.08375 kilohertz 3rd band pass 3rd function and 1.12625 kilohertz 3rd band pass 3rd function and 1.1475 kilohertz 3rd band pass 3rd function
Thread Size:
0.138 inches
Frequency Band Width Per Function:
1.08375 kilohertz 1st band pass and 1.12625 kilohertz 1st band pass
Frequency Band Width Per Function:
1.08375 kilohertz 2nd band pass and 1.12625 kilohertz 2nd band pass
Frequency Band Width Per Function:
1.08375 kilohertz 3rd band pass and 1.12625 kilohertz 3rd band pass
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 1st band pass 1st function and 30.0 1st band pass 1st function
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 2nd band pass 2nd function and 30.0 2nd band pass 2nd function
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 3rd band pass 3rd function and 30.0 3rd band pass 3rd function
Maximum Dielectric Withstanding Dc Voltage:
500.0 volts at sea level
Style Designator:
Rectangular terminal/terminals on one surface
Item Name:
Tunable Bandreject Filter
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC