Product Features
Three filtered functions; one unfiltered function
Technical Specifications of NSN
Overall Length:
8.000 inches
Body Length:
8.000 inches
Body Height:
3.500 inches
Unthreaded Mounting Hole Diameter:
0.172 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
6.500 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
5.500 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Reference Frequency Per Function:
175.0 2nd radio interference pulses per second
Reference Frequency Per Function:
175.0 2nd radio interference two phase to three phase
Reference Frequency Per Function:
175.0 2nd radio interference two phase to two phase
Source Impedance Rating Per Function:
50.0 ohms 1st band suppression
Source Impedance Rating Per Function:
50.0 ohms 2nd band suppression
Source Impedance Rating Per Function:
50.0 ohms 3rd band suppression
Load Impedance Per Function:
50.0 ohms 1st band suppression
Load Impedance Per Function:
50.0 ohms 3rd band suppression
Load Impedance Per Function:
50.0 ohms 2nd band suppression
Principal Circuitry Type Per Function:
Inductance-capacitance 1st band suppression
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd band suppression
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd band suppression
Mounting Facility Type And Quantity:
4 unthreaded hole
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 3rd band suppression
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 2nd band suppression
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 1st band suppression
Functional Terminal Type And Quantity:
3 screw input 1st function
Functional Terminal Type And Quantity:
3 screw output 2nd function
Specified Frequencies Of Discrimination Per Function:
100.00 kilohertz 2nd band suppression and 150.00 kilohertz 2nd band suppression and 200.00 kilohertz 2nd band suppression and 250.00 kilohertz 2nd band suppression
Specified Frequencies Of Discrimination Per Function:
100.00 kilohertz 3rd band suppression and 150.00 kilohertz 3rd band suppression and 200.00 kilohertz 3rd band suppression and 250.00 kilohertz 3rd band suppression
Specified Frequencies Of Discrimination Per Function:
100.00 kilohertz 1st band suppression and 150.00 kilohertz 1st band suppression and 200.00 kilohertz 1st band suppression and 250.00 kilohertz 1st band suppression
Frequency Band Width Per Function:
150.00 kilohertz 1st band suppression and 200.00 kilohertz 1st band suppression
Frequency Band Width Per Function:
150.00 kilohertz 2nd band suppression and 200.00 kilohertz 2nd band suppression
Frequency Band Width Per Function:
150.00 kilohertz 3rd band suppression and 200.00 kilohertz 3rd band suppression
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 1st band suppression and 60.0 1st band suppression
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 2nd band suppression and 60.0 2nd band suppression
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 3rd band suppression and 60.0 3rd band suppression
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Specification Data:
30003-1185as156 manufacturers specification control
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC