Detail Specifications
Operating Tempurature Range:
-20.0/+155.0 degrees fahrenheit
Reference Frequency Per Function:
30.0 megahertz blank
Source Impedance Rating Per Function:
50.0 ohms blank
Load Impedance Per Function:
50.0 ohms blank
Principal Circuitry Type Per Function:
Inductance-capacitance blank
Insertion Loss At Reference Frequency Per Function In Decibels:
5.0 blank
Functional Terminal Type And Quantity:
2 pin input 1st function
Functional Terminal Type And Quantity:
2 pin output 2nd function
Specified Frequencies Of Discrimination Per Function:
29.9725 megahertz blank and 29.989 megahertz blank and 30.011 megahertz blank and 30.0275 megahertz blank
Frequency Band Width Per Function:
29.989 megahertz blank and 30.011 megahertz blank
Discrimination At Specificationified Frequencies Per Function In Decibels:
40.0 blank and 3.0 blank and 3.0 blank and 40.0 blank
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC