Product Features
Two filtered functions
Technical Specifications of NSN
Overall Length:
Between 3.090 inches and 3.100 inches
Body Length:
Between 2.940 inches and 2.950 inches
Body Width:
Between 1.050 inches and 1.060 inches
Body Height:
Between 0.740 inches and 0.760 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 0.940 inches and 0.960 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 0.410 inches and 0.430 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Operating Tempurature Range:
-55.0 to 85.0 degrees celsius
Reference Frequency Per Function:
147.5 single radio interference pulses per second
Reference Frequency Per Function:
147.5 single radio interference two phase to two phase
Reference Frequency Per Function:
147.5 kilohertz 2nd band pass 2nd function
Source Impedance Rating Per Function:
1.0 kilohms 1st band pass
Source Impedance Rating Per Function:
1.0 kilohms 2nd band pass
Source Impedance Rating Per Function:
1.0 kilohms 2nd band pass 2nd function
Load Impedance Per Function:
68.0 kilohms 1st band pass
Load Impedance Per Function:
68.0 kilohms 2nd band pass
Load Impedance Per Function:
68.0 kilohms 2nd band pass 2nd function
Principal Circuitry Type Per Function:
Inductance-capacitance 1st band pass 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd band pass 2nd function
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
4 threaded stud
Features Provided:
Nut and shock resistant
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 2nd band pass
Functional Terminal Type And Quantity:
2 wire loop input 1st function
Functional Terminal Type And Quantity:
2 wire loop output 2nd function
Maximum Dielectric Withstanding Ac Rms Voltage:
100.0 volts at sea level
Specified Frequencies Of Discrimination Per Function:
143.00 kilohertz 2nd band pass 2nd function and 147.00 kilohertz 2nd band pass 2nd function and 148.00 kilohertz 2nd band pass 2nd function and 152.00 kilohertz 2nd band pass 2nd function
Specified Frequencies Of Discrimination Per Function:
143.00 kilohertz 1st band pass 1st function and 147.00 kilohertz 1st band pass 1st function and 148.00 kilohertz 1st band pass 1st function and 152.00 kilohertz 1st band pass 1st function
Thread Size:
0.112 inches
Frequency Band Width Per Function:
147.00 kilohertz 2nd band pass and 148.00 kilohertz 2nd band pass
Frequency Band Width Per Function:
147.00 kilohertz 1st band pass and 148.00 kilohertz 1st band pass
Frequency Band Width Per Function:
147.00 kilohertz 2nd band pass and 148.00 kilohertz 2nd band pass
Frequency Band Width Per Function:
147.00 kilohertz 1st band pass and 148.00 kilohertz 1st band pass
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 1st band pass 1st function and 40.0 1st band pass 1st function
Discrimination At Specificationified Frequencies Per Function In Decibels:
3.0 2nd band pass 2nd function and 40.0 2nd band pass 2nd function
Unpackaged Unit Weight:
0.123 pounds
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Specification Data:
10001-2234371 manufacturers specification control
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC