Detail Specifications
Body Length:
3.031 inches
Body Height:
1.375 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.750 inches
Reference Frequency Per Function:
13.1 single radio interference two phase to two phase
Reference Frequency Per Function:
13.1 single radio interference pulses per second
Source Impedance Rating Per Function:
50.0 kilohms blank
Load Impedance Per Function:
100.0 kilohms blank
Input Impedance Per Function W/load:
50.0 kilohms 1st band pass
Input Impedance Per Function W/load:
50.0 kilohms 2nd band pass
Output Impedance Per Function W/source Across Input:
100.0 kilohms 1st band pass
Output Impedance Per Function W/source Across Input:
100.0 kilohms 2nd band pass
Principal Circuitry Type Per Function:
Inductance-resistance 1st band pass 1st function
Principal Circuitry Type Per Function:
Inductance-resistance 2nd band pass 2nd function
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
2 threaded hole
Insertion Loss At Reference Frequency Per Function In Decibels:
1.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
1.0 2nd band pass
Functional Terminal Type And Quantity:
1 component socket input-output/ground
Specified Frequencies Of Discrimination Per Function:
11.30 kilohertz 1st band pass 1st function and 12.60 kilohertz 1st band pass 1st function and 13.60 kilohertz 1st band pass 1st function and 15.00 kilohertz 1st band pass 1st function
Specified Frequencies Of Discrimination Per Function:
11.30 kilohertz 2nd band pass 2nd function and 12.60 kilohertz 2nd band pass 2nd function and 13.60 kilohertz 2nd band pass 2nd function and 15.00 kilohertz 2nd band pass 2nd function
Thread Size:
0.138 inches
Frequency Band Width Per Function:
12.60 kilohertz 1st band pass and 13.60 kilohertz 1st band pass
Frequency Band Width Per Function:
12.60 kilohertz 2nd band pass and 13.60 kilohertz 2nd band pass
Discrimination At Specificationified Frequencies Per Function In Decibels:
60.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 60.0 2nd band pass 2nd function
Discrimination At Specificationified Frequencies Per Function In Decibels:
60.0 1st band pass 1st function and 3.0 1st band pass 1st function and 3.0 1st band pass 1st function and 60.0 1st band pass 1st function
Style Designator:
Rectangular terminal/terminals on one surface
Item Name:
Quartz Crystal Filter
Manufacturer Part Numbers
No other part numbers with same form, fit, and function found.