Detail Specifications
Overall Height:
7.000 inches
Body Length:
2.750 inches
Body Height:
6.500 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.250 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.125 inches
Operating Tempurature Range:
-15.0/+45.0 degrees celsius
Reference Frequency Per Function:
12.3 single radio interference pulses per second
Reference Frequency Per Function:
12.3 single radio interference two phase to two phase
Input Impedance Per Function W/load:
1.0 kilohms 1st band pass
Input Impedance Per Function W/load:
1.0 kilohms 2nd band pass
Output Impedance Per Function W/source Across Input:
10.0 kilohms 1st band pass
Output Impedance Per Function W/source Across Input:
10.0 kilohms 2nd band pass
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
4 threaded stud
Insertion Loss At Reference Frequency Per Function In Decibels:
1.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
1.0 2nd band pass
Functional Terminal Type And Quantity:
2 tab, solder lug ground 3rd function
Functional Terminal Type And Quantity:
2 tab, solder lug input 1st function
Functional Terminal Type And Quantity:
2 tab, solder lug output 2nd function
Specified Frequencies Of Discrimination Per Function:
11.93 kilohertz 1st band pass 1st function and 12.03 kilohertz 1st band pass 1st function and 12.63 kilohertz 1st band pass 1st function and 12.83 kilohertz 1st band pass 1st function
Specified Frequencies Of Discrimination Per Function:
12.25 kilohertz 2nd band pass 2nd function and 12.28 kilohertz 2nd band pass 2nd function and 12.32 kilohertz 2nd band pass 2nd function and 12.35 kilohertz 2nd band pass 2nd function
Thread Size:
0.164 inches
Frequency Band Width Per Function:
12.03 kilohertz 1st band pass and 12.63 kilohertz 1st band pass
Frequency Band Width Per Function:
12.286 kilohertz 2nd band pass and 12.314 kilohertz 2nd band pass
Discrimination At Specificationified Frequencies Per Function In Decibels:
40.0 1st band pass 1st function and 3.0 1st band pass 1st function and 3.0 1st band pass 1st function and 40.0 1st band pass 1st function
Discrimination At Specificationified Frequencies Per Function In Decibels:
40.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 3.0 2nd band pass 2nd function and 40.0 2nd band pass 2nd function
Style Designator:
Rectangular terminal/terminals on one surface
Item Name:
Band Pass Filter
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC