Detail Specifications
Overall Length:
4.300 inches
Overall Height:
0.500 inches
Body Length:
3.540 inches
Unthreaded Mounting Hole Diameter:
0.154 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.900 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
2.600 inches
Operating Tempurature Range:
-54.0/+71.0 degrees celsius
Reference Frequency Per Function:
7.2 hercules no.5599.1 pulses per second
Reference Frequency Per Function:
7.2 hercules no.5599.1 two phase to two phase
Source Impedance Rating Per Function:
50.0 ohms 1st band pass
Source Impedance Rating Per Function:
50.0 ohms 2nd band pass
Load Impedance Per Function:
50.0 ohms 1st band pass
Load Impedance Per Function:
50.0 ohms 2nd band pass
Principal Circuitry Type Per Function:
Crystal 1st band pass 1st function
Principal Circuitry Type Per Function:
Crystal 2nd band pass 2nd function
Mounting Facility Type And Quantity:
8 unthreaded hole
Insertion Loss At Reference Frequency Per Function In Decibels:
2.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
2.0 2nd band pass
Functional Terminal Type And Quantity:
4 pin ground 3rd function
Functional Terminal Type And Quantity:
4 pin input 1st function
Functional Terminal Type And Quantity:
4 pin output 2nd function
Specified Frequencies Of Discrimination Per Function:
7.1972 megahertz 1st band pass 1st function and 7.1989 megahertz 1st band pass 1st function and 7.2010 megahertz 1st band pass 1st function and 7.2028 megahertz 1st band pass 1st function
Specified Frequencies Of Discrimination Per Function:
7.1972 megahertz 2nd band pass 2nd function and 7.1989 megahertz 2nd band pass 2nd function and 7.2010 megahertz 2nd band pass 2nd function and 7.2028 megahertz 2nd band pass 2nd function
Frequency Band Width Per Function:
7.1989 megahertz 1st band pass and 7.2010 megahertz 1st band pass
Frequency Band Width Per Function:
7.1989 megahertz 2nd band pass and 7.2010 megahertz 2nd band pass
Discrimination At Specificationified Frequencies Per Function In Decibels:
50.0 2nd band pass 2nd function and 2.0 2nd band pass 2nd function and 2.0 2nd band pass 2nd function and 50.0 2nd band pass 2nd function
Discrimination At Specificationified Frequencies Per Function In Decibels:
50.0 1st band pass 1st function and 2.0 1st band pass 1st function and 2.0 1st band pass 1st function and 50.0 1st band pass 1st function
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Filter,crystal
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC