Product Technical Spec.
Overall Height:
0.750 inches
Body Length:
3.500 inches
Body Height:
0.600 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.000 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
2.250 inches
Operating Tempurature Range:
-29.0/+85.0 degrees celsius
Reference Frequency Per Function:
11.2 single radio interference pulses per second
Reference Frequency Per Function:
17.6 single radio interference two phase to two phase
Reference Frequency Per Function:
24.0 single radio interference two phase to three phase
Source Impedance Rating Per Function:
1.0 kilohms 3rd band pass
Source Impedance Rating Per Function:
1.0 kilohms 1st band pass
Source Impedance Rating Per Function:
1.0 kilohms 2nd band pass
Load Impedance Per Function:
1.0 kilohms 2nd band pass
Load Impedance Per Function:
1.0 kilohms 3rd band pass
Load Impedance Per Function:
1.0 kilohms 1st band pass
Mounting Facility Type And Quantity:
7 tab
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 3rd band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 1st band pass
Insertion Loss At Reference Frequency Per Function In Decibels:
3.0 2nd band pass
Functional Terminal Type And Quantity:
1 pin input 1st function
Functional Terminal Type And Quantity:
1 pin output 2nd function
Functional Terminal Type And Quantity:
2 pin ground 3rd function
Specified Frequencies Of Discrimination Per Function:
16.00 kilohertz 2nd band pass 2nd function and 16.40 kilohertz 2nd band pass 2nd function and 18.80 kilohertz 2nd band pass 2nd function and 19.20 kilohertz 2nd band pass 2nd function
Specified Frequencies Of Discrimination Per Function:
22.40 kilohertz 3rd band pass 3rd function and 22.80 kilohertz 3rd band pass 3rd function and 25.20 kilohertz 3rd band pass 3rd function and 25.60 kilohertz 3rd band pass 3rd function
Specified Frequencies Of Discrimination Per Function:
9.60 kilohertz 1st band pass 1st function and 10.00 kilohertz 1st band pass 1st function and 12.40 kilohertz 1st band pass 1st function and 12.80 kilohertz 1st band pass 1st function
Frequency Band Width Per Function:
10.00 kilohertz 1st band pass and 12.40 kilohertz 1st band pass
Frequency Band Width Per Function:
16.40 kilohertz 2nd band pass and 18.80 kilohertz 2nd band pass
Frequency Band Width Per Function:
22.80 kilohertz 3rd band pass and 25.20 kilohertz 3rd band pass
Discrimination At Specificationified Frequencies Per Function In Decibels:
23.0 1st band pass 1st function and 8.0 1st band pass 1st function and 8.0 1st band pass 1st function and 23.0 1st band pass 1st function
Discrimination At Specificationified Frequencies Per Function In Decibels:
23.0 3rd band pass 3rd function and 8.0 3rd band pass 3rd function and 8.0 3rd band pass 3rd function and 23.0 3rd band pass 3rd function
Discrimination At Specificationified Frequencies Per Function In Decibels:
23.0 2nd band pass 2nd function and 8.0 2nd band pass 2nd function and 8.0 2nd band pass 2nd function and 23.0 2nd band pass 2nd function
Body Surface Treatment:
Tin
Unpackaged Unit Weight:
3.000 ounces
Style Designator:
Rectangular terminal/terminals on one surface
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS