Phase shifter shall be capable of handling peak powers at 2 watts cont wav (cw) ; shall not vary from liner more than 3.0 degs over any 2.5 mhz band; control voltages-low state 0-0.8 volts, high state 2.0-2.5 volts; rf switch-sgl pole; dbl throw switch both input and output for connecting phase shifter to either of 2 inputs or outputs independetly; vswr 1.8 to 1 in 50 ohm system; st dev. Not to exceed 2.25 degs