Product Technical Spec.
Power Line Frequency Rating Per Function In Hertz:
60.0 1st radio interference60.0 2nd radio interference60.0 3rd radio interference60.0 4th radio interference60.0 5th radio interference60.0 6th radio interference
Operating Current Rating Per Function In Amps:
0.05 1st radio interference0.05 2nd radio interference0.05 3rd radio interference0.05 4th radio interference0.05 5th radio interference0.05 6th radio interference
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
22 terminal
Functional Terminal Type And Quantity:
22 friction w/grounding strap and pin input-output
Operating Voltage Rating And Type Per Function:
32.0 volts dc 1st radio interference 1st function32.0 volts dc 2nd radio interference 2nd function10.0 volts dc 3rd radio interference 3rd function10.0 volts dc 4th radio interference 4th function650.0 volts dc 5th radio interference 5th function650.0 volts dc 6th radio interference 6th function
Body Surface Treatment:
Cadmium
Precious Material And Location:
Contact surfaces gold
Item Name:
Filter,radio Interference
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC