Product Features
11 functions
Detail Specifications
Overall Length:
Between 7.480 inches and 7.520 inches
Overall Height:
4.310 inches
Overall Width:
Between 3.540 inches and 3.580 inches
Body Length:
Between 6.360 inches and 6.400 inches
Body Width:
Between 2.420 inches and 2.460 inches
Unthreaded Mounting Hole Diameter:
0.196 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 7.115 inches and 7.135 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
3.187 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Average Life Rating In Hours:
1000.0
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
1000.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
1000.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
1000.0 3rd radio interference
Operating Current Rating Per Function In Amps:
0.5 5th radio interference
Operating Current Rating Per Function In Amps:
0.5 6th radio interference
Operating Current Rating Per Function In Amps:
10.0 1st radio interference
Operating Current Rating Per Function In Amps:
12.0 3rd radio interference
Operating Current Rating Per Function In Amps:
12.0 4th radio interference
Operating Current Rating Per Function In Amps:
2.0 2nd radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts ac 1st radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts ac 3rd radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts ac 4th radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts dc 2nd radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts dc 5th radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts dc 6th radio interference
Input Terminal Manufacturer Code:
96906
Mounting Facility Type And Quantity:
20 unthreaded hole
Functional Terminal Type And Quantity:
11 threaded stud output 2nd function
Functional Terminal Type And Quantity:
2 connector, receptacle input 1st function and 1 connector, plug input 1st function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 6th radio interference 6th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
Style Designator:
Rectangular terminal/terminals on adjacent surfaces
Test Data Document:
97151-68d40003 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC