Technical Specifications of NSN
Overall Length:
8.312 inches
Overall Height:
2.000 inches
Mounting Slot Width:
0.219 inches
Body Length:
7.000 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
7.312 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
4.750 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Operating Tempurature Range:
-55.0 to 85.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference 1st function
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function:
50.0 ohms 3rd radio interference 3rd function
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference 3rd function
Operating Current Rating Per Function In Amps:
30.0 2nd radio interference
Operating Current Rating Per Function In Amps:
30.0 3rd radio interference
Operating Current Rating Per Function In Amps:
30.0 1st radio interference
Operating Current Rating Per Function In Amps:
30.0 1st radio interference 1st function
Operating Current Rating Per Function In Amps:
30.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
30.0 3rd radio interference 3rd function
Maximum Voltage Drop Per Function:
500.0 millivolts ac 2nd radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts ac 3rd radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts ac 1st radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts ac 3rd radio interference 3rd function
Mounting Facility Screw Thread Series Designator:
Unf
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 slot
Mounting Facility Type And Quantity:
4 threaded stud
Mounting Facility Type And Quantity:
4 threaded stud 1st function
Functional Terminal Type And Quantity:
3 threaded stud output 2nd function
Functional Terminal Type And Quantity:
3 threaded stud input 1st function
Operating Voltage Rating And Type Per Function:
130.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
130.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
130.0 volts ac 3rd radio interference 3rd function
Thread Size:
0.190 inches
Body Surface Treatment:
Tin
Unpackaged Unit Weight:
8.312 pounds
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC