Detail Specifications
Overall Length:
8.240 inches
Mounting Slot Width:
0.250 inches
Body Length:
6.500 inches
Body Height:
3.250 inches
Vibration Resistance Range In Hertz:
+4.0/+33.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
4.750 inches
Operating Tempurature Range:
-0.0/+65.0 degrees celsius
Average Life Rating In Hours:
10000.0
End Application:
Radar set an/sps-48e
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
63.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
63.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
63.0 1st radio interference
Operating Current Rating Per Function In Amps:
40.0 1st radio interference
Operating Current Rating Per Function In Amps:
40.0 2nd radio interference
Operating Current Rating Per Function In Amps:
40.0 3rd radio interference
Maximum Voltage Drop Per Function:
2.5 volts ac 1st radio interference
Maximum Voltage Drop Per Function:
2.5 volts ac 3rd radio interference
Maximum Voltage Drop Per Function:
2.5 volts ac 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Maximum Tempurature Rise:
40.0 degrees celsius
Mounting Facility Screw Thread Series Designator:
Unf
Mounting Facility Type And Quantity:
3 slot
Mounting Facility Type And Quantity:
6 threaded stud
Functional Terminal Type And Quantity:
3 threaded stud output 2nd function
Functional Terminal Type And Quantity:
3 threaded stud input 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Thread Size:
0.190 inches
Maximum Dielectric Withstanding Dc Voltage:
483.0 volts at sea level
Body Surface Treatment:
Tin
Unpackaged Unit Weight:
12.000 ounces
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Filter Powerline
Manufacturer Part Numbers
No other part numbers with same form, fit, and function found.