#5049013 Magneto Filter Assembly | Filters And Networks

5049013

Radio Frequency Interfere Filter

NSN 5915-00-432-9284

DEMIL
Shelf Life
UOM
NIIN
Demil:
NO
Shelf Life:
UOM:
NIIN:
004329284

Product Features

Ten functions

Detail Specifications

Overall Height:
3.000 inches
Body Length:
3.750 inches
Body Width:
2.250 inches
Body Height:
2.500 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.000 inches
Vibration Resistance Range In Hertz:
+5.0/+500.0
Vibration Resistance Range In Hertz:
+5.0 to 500.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.500 inches
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Operating Tempurature Range:
-55.0 to 85.0 degrees celsius
Average Life Rating In Hours:
250.0
Source Impedance Rating Per Function:
50.0 ohms blank
Load Impedance Per Function:
50.0 ohms blank
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 6th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference 5th function
Power Line Frequency Rating Per Function In Hertz:
400.0 6th radio interference 6th function
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference 3rd function
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference 4th function
Operating Current Rating Per Function In Amps:
4.0 1st radio interference
Operating Current Rating Per Function In Amps:
4.0 2nd radio interference
Operating Current Rating Per Function In Amps:
4.0 3rd radio interference
Operating Current Rating Per Function In Amps:
4.0 4th radio interference
Operating Current Rating Per Function In Amps:
4.0 5th radio interference
Operating Current Rating Per Function In Amps:
4.0 6th radio interference
Operating Current Rating Per Function In Amps:
4.0 1st radio interference 1st function
Operating Current Rating Per Function In Amps:
4.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
4.0 3rd radio interference 3rd function
Operating Current Rating Per Function In Amps:
4.0 4th radio interference 4th function
Operating Current Rating Per Function In Amps:
4.0 5th radio interference 5th function
Operating Current Rating Per Function In Amps:
4.0 6th radio interference 6th function
Maximum Tempurature Rise:
25.0 degrees celsius
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 threaded stud
Functional Terminal Type And Quantity:
10 wire hook input 1st function
Functional Terminal Type And Quantity:
10 wire hook output 2nd function
Maximum Dielectric Withstanding Ac Rms Voltage:
300.0 volts at sea level
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 6th radio interference 6th function
Maximum Dielectric Withstanding Dc Voltage:
56.0 volts at sea level
Unpackaged Unit Weight:
2.200 pounds
Style Designator:
Rectangular terminal/terminals on one surface
NSN:
5915-00-432-9284
Item Name:
Magneto Filter Assembly
Cage Code:
33095

Manufacturer Part Numbers

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
B46N0119-1
Cage Code:
12464
RNCC:
3
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
5049-013
Cage Code:
0LSP2
RNCC:
5
RNVC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
RF04355B
Cage Code:
13619
RNCC:
5
RNVC:
2
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
Part Number:
9633-100-9000
Cage Code:
12294
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
RF4355B
Cage Code:
13619
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 5049013 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Filters And Networks
--------- Radio Frequency Interfere Filters
------------ P/N 5049013

Best-Selling Products A collection of our most popular products

Last Updated: 12/22/2024