Product Features
Forty-one filtered functions
Detail Specifications
Overall Length:
1.590 inches
Overall Height:
1.828 inches
Overall Width:
1.828 inches
Vibration Resistance Range In Hertz:
+10.0/+500.0
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
End Application:
Countermeasures set, special purpose an/mlq-34
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 6th radio interference
Operating Current Rating Per Function In Amps:
7.5 1st radio interference
Operating Current Rating Per Function In Amps:
7.5 3rd radio interference
Operating Current Rating Per Function In Amps:
7.5 4th radio interference
Operating Current Rating Per Function In Amps:
7.5 5th radio interference
Operating Current Rating Per Function In Amps:
7.5 6th radio interference
Operating Current Rating Per Function In Amps:
7.5 2nd radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 1st radio interference and 2.0 volts dc 1st radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 1st radio interference and 2.0 volts dc 2nd radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 1st radio interference and 2.0 volts dc 3rd radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 4th radio interference and 2.0 volts dc 4th radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 5th radio interference and 2.0 volts dc 5th radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 6th radio interference and 2.0 volts dc 6th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
Input Terminal Manufacturer Code:
57958
Input Terminal Identification:
Mil-c-26074
Output Terminal Manufacturer Code:
57958
Output Terminal Identification:
Mil-c-26074
Maximum Tempurature Rise:
25.0 degrees celsius
Full Load Insertion Loss Frequencies In Megahertz:
1.0 and 2.0 and 10.0 and 100.0 and 500.0 and 1000.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
2.0 and 5.0 and 18.0 and 50.0 and 60.0 and 60.0
Mounting Facility Screw Thread Series Designator:
Unf
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
1 threaded bushing
Functional Terminal Type And Quantity:
41 friction w/grounding strap and pin input-output
Operating Voltage Rating And Type Per Function:
120.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function
Thread Size:
0.812 inches
Maximum Dielectric Withstanding Dc Voltage:
1.2 kilovolts at sea level
Body Surface Treatment:
Nickel
Precious Material And Location:
Contact surfaces gold and ground plane surfaces silver
Precious Material:
Gold and silver
Style Designator:
Filter connector
Item Name:
Electromotive Force Interference Filter
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC