Product Technical Spec.
Overall Length:
2.500 inches
Overall Height:
0.750 inches
Overall Width:
2.500 inches
Body Length:
1.750 inches
Unthreaded Mounting Hole Diameter:
0.188 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
2.125 inches
Input Impedance Per Function W/load:
50.0 ohms 2nd radio interference
Input Impedance Per Function W/load:
50.0 ohms 1st radio interference
Input Impedance Per Function W/load:
50.0 ohms 1st radio interference 1st function
Input Impedance Per Function W/load:
50.0 ohms 2nd radio interference 2nd function
Output Impedance Per Function W/source Across Input:
50.0 ohms 2nd radio interference
Output Impedance Per Function W/source Across Input:
50.0 ohms 1st radio interference
Output Impedance Per Function W/source Across Input:
50.0 ohms 1st radio interference 1st function
Output Impedance Per Function W/source Across Input:
50.0 ohms 2nd radio interference 2nd function
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
5.0 1st radio interference
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
5.0 1st radio interference 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference 2nd function
Mounting Facility Type And Quantity:
2 unthreaded hole
Functional Terminal Type And Quantity:
1 tab, solder lug ground 3rd function
Functional Terminal Type And Quantity:
2 tab, solder lug input 1st function
Functional Terminal Type And Quantity:
2 tab, solder lug output 2nd function
Operating Voltage Rating And Type Per Function:
230.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Maximum Dielectric Withstanding Dc Voltage:
2.0 kilovolts at sea level
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Ac Power Filter
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC