Product Technical Spec.
Overall Length:
Between 13.970 inches and 14.030 inches
Mounting Slot Width:
Between 0.590 inches and 0.650 inches
Body Length:
Between 11.970 inches and 12.030 inches
Body Width:
Between 6.470 inches and 6.530 inches
Body Height:
Between 4.720 inches and 4.780 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
Between 5.470 inches and 5.530 inches
End Application:
4920-01-187-4068 test system, aut
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
63.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
63.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
63.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
63.0 4th radio interference
Operating Current Rating Per Function In Amps:
60.0 2nd radio interference
Operating Current Rating Per Function In Amps:
60.0 3rd radio interference
Operating Current Rating Per Function In Amps:
60.0 4th radio interference
Operating Current Rating Per Function In Amps:
60.0 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Mounting Facility Screw Thread Series Designator:
Unc
Mounting Facility Type And Quantity:
2 slot
Mounting Facility Type And Quantity:
4 threaded stud
Functional Terminal Type And Quantity:
1 threaded stud ground 3rd function
Functional Terminal Type And Quantity:
4 threaded stud input 1st function
Functional Terminal Type And Quantity:
4 threaded stud output 2nd function
Operating Voltage Rating And Type Per Function:
250.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
250.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
250.0 volts ac 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
250.0 volts ac 3rd radio interference 3rd function
Thread Size:
0.250 inches
Maximum Dielectric Withstanding Dc Voltage:
2.2 kilovolts at sea level
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Specification Data:
97384-60585-90037 manufacturers specification control
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC