#60911871 Keying Filter | Filters And Networks

60911871

Radio Frequency Interfere Filter

NSN 5915-00-528-9286

DEMIL
Shelf Life
UOM
NIIN
Demil:
DEMIL/MLI
Shelf Life:
N/A
UOM:
EA
NIIN:
005289286

Product Features

Terminals on opposite surfaces

Technical Specifications of NSN

Overall Height:
3.563 inches
Body Length:
4.000 inches
Body Width:
2.500 inches
Body Height:
3.063 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.250 inches
Vibration Resistance Range In Hertz:
+20.0/+500.0
Operating Tempurature Range:
-54.0/+80.0 degrees celsius
Average Life Rating In Hours:
50000.0
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 6th radio interference
Operating Current Rating Per Function In Amps:
1.5 1st radio interference
Operating Current Rating Per Function In Amps:
1.5 2nd radio interference
Operating Current Rating Per Function In Amps:
1.5 3rd radio interference
Operating Current Rating Per Function In Amps:
1.5 4th radio interference
Operating Current Rating Per Function In Amps:
1.5 5th radio interference
Operating Current Rating Per Function In Amps:
1.5 6th radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 2nd radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 1st radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 3rd radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 4th radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 5th radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 6th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
Input Terminal Manufacturer Code:
71468
Input Terminal Identification:
Dpxbme26-34p0000
Inclosure Type:
Encased
Mounting Facility Type And Quantity:
6 terminal
Mounting Facility Type And Quantity:
1 connector
Functional Terminal Type And Quantity:
1 connector, receptacle input 1st function
Functional Terminal Type And Quantity:
6 threaded stud output 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 6th radio interference 6th function
Body Material:
Metal
Style Designator:
Rectangular terminal/terminals on one surface
NSN:
5915-00-528-9286
Item Name:
Keying Filter
Cage Code:
03640

Other Related Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
10B549-1
Cage Code:
13058
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
6091187-1
Cage Code:
54991
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
6091187-1
Cage Code:
59901
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
6091187-1
Cage Code:
33095
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
10B549-1
Cage Code:
13058
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
6091187-1
Cage Code:
54991
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
6091187-1
Cage Code:
59901
RNCC:
5
RNVC:
2
RNAAC:
TX
Status:
A
MSDS:
SADC:
Part Number:
6091187-1
Cage Code:
33095
RNCC:
5
RNVC:
9
RNAAC:
TX
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number 60911871 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Filters And Networks
--------- Radio Frequency Interfere Filters
------------ P/N 60911871

Best-Selling Products A collection of our most popular products

Last Updated: 12/21/2024