Overall Height:
3.500 inches
Body Length:
9.500 inches
Body Height:
2.500 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
8.250 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
6.375 inches
Operating Tempurature Range:
-0.0/+70.0 degrees celsius
End Application:
Console, input-output oj-17 (v) 1/uyk
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Operating Current Rating Per Function In Amps:
35.0 1st radio interference
Operating Current Rating Per Function In Amps:
35.0 2nd radio interference
Operating Current Rating Per Function In Amps:
35.0 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance-resistance 3rd radio interference
Maximum Tempurature Rise:
60.0 degrees celsius
Mounting Facility Screw Thread Series Designator:
Unf
Mounting Facility Type And Quantity:
6 threaded hole
Functional Terminal Type And Quantity:
3 threaded stud output 2nd function
Functional Terminal Type And Quantity:
3 threaded stud input 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Thread Size:
0.250 inches
Maximum Dielectric Withstanding Dc Voltage:
800.0 volts at sea level
Unpackaged Unit Weight:
18.000 pounds
Style Designator:
Rectangular terminal/terminals on one surface
Test Data Document:
05869-713757 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Item Name:
Ac Ripple Filter
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC