Technical Specifications of NSN
Overall Length:
1.000 inches
Body Outside Diameter:
Between 0.135 inches and 0.145 inches
Operating Tempurature Range:
-25.0/+85.0 degrees celsius
End Application:
6625-01-348-4550 generator, signal
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Operating Current Rating Per Function In Amps:
15.0 1st radio interference
Operating Current Rating Per Function In Amps:
15.0 4th radio interference
Operating Current Rating Per Function In Amps:
15.0 5th radio interference
Operating Current Rating Per Function In Amps:
15.0 6th radio interference
Operating Current Rating Per Function In Amps:
15.0 2nd radio interference
Operating Current Rating Per Function In Amps:
15.0 3rd radio interference
Full Load Insertion Loss Frequencies In Megahertz:
50.0 and 100.0 and 300.0 and 500.0 and 1000.0 and 5000.0 and 10000.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
8.0 and 12.0 and 25.0 and 35.0 and 45.0 and 45.0 and 45.0
Mounting Facility Type And Quantity:
2 terminal
Functional Terminal Type And Quantity:
1 pin input 1st function
Functional Terminal Type And Quantity:
1 pin output 2nd function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
100.0 volts dc 6th radio interference 6th function
Maximum Dielectric Withstanding Dc Voltage:
250.0 volts at sea level
Precious Material And Location:
Contact surfaces gold
Style Designator:
Round terminal/terminals on opposite surfaces
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC