Product Technical Spec.
Overall Length:
Between 2.750 inches and 2.844 inches
Overall Height:
1.500 inches
Overall Width:
2.000 inches
Body Length:
2.000 inches
Unthreaded Mounting Hole Diameter:
Between 0.172 inches and 0.202 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 2.360 inches and 2.390 inches
Source Impedance Rating Per Function:
300.0 ohms 1st radio interference
Source Impedance Rating Per Function:
300.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
300.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
300.0 ohms 4th radio interference
Load Impedance Per Function:
300.0 ohms 4th radio interference
Load Impedance Per Function:
300.0 ohms 1st radio interference
Load Impedance Per Function:
300.0 ohms 2nd radio interference
Load Impedance Per Function:
300.0 ohms 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
70.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
70.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
70.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
70.0 4th radio interference
Operating Current Rating Per Function In Amps:
60.0 2nd radio interference
Operating Current Rating Per Function In Amps:
60.0 3rd radio interference
Operating Current Rating Per Function In Amps:
60.0 4th radio interference
Operating Current Rating Per Function In Amps:
60.0 1st radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts ac 2nd radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts ac 3rd radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts ac 1st radio interference
Maximum Voltage Drop Per Function:
500.0 millivolts ac 4th radio interference
Mounting Facility Type And Quantity:
2 unthreaded hole
Functional Terminal Type And Quantity:
1 wire lead ground 3rd function
Functional Terminal Type And Quantity:
4 wire lead output 2nd function
Functional Terminal Type And Quantity:
4 wire lead input 1st function
Operating Voltage Rating And Type Per Function:
30.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
30.0 volts ac 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
30.0 volts ac 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
30.0 volts ac 1st radio interference 1st function
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Emf Interference Filter
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC