Detail Specifications
Overall Length:
1.720 inches
Overall Height:
0.750 inches
Overall Width:
1.000 inches
Body Length:
1.120 inches
Unthreaded Mounting Hole Diameter:
0.140 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
1.430 inches
Vibration Resistance Range In Hertz:
+10.0/+2000.0
Operating Tempurature Range:
-55.0/+85.0 degrees celsius
Average Life Rating In Hours:
10000.0
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Operating Current Rating Per Function In Amps:
5.0 1st radio interference
Operating Current Rating Per Function In Amps:
5.0 4th radio interference
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference
Operating Current Rating Per Function In Amps:
5.0 3rd radio interference
Mounting Facility Type And Quantity:
2 unthreaded hole
Functional Terminal Type And Quantity:
2 wire lead ground 3rd function
Functional Terminal Type And Quantity:
4 wire lead input 1st function
Operating Voltage Rating And Type Per Function:
300.0 volts ac 1st radio interference 1st function and 300.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
300.0 volts ac 2nd radio interference 2nd function and 300.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
300.0 volts ac 3rd radio interference 3rd function and 300.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
300.0 volts ac 4th radio interference 4th function and 300.0 volts dc 4th radio interference 4th function
Maximum Dielectric Withstanding Dc Voltage:
600.0 volts at sea level
Body Surface Treatment:
Tin
Unpackaged Unit Weight:
56.000 grams
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Emf Interference Filter
Manufacturer Part Numbers
No other part numbers with same form, fit, and function found.