Product Features
Nuclear hardness critical item
Product Technical Spec.
Overall Length:
1.685 inches
Overall Height:
Between 1.020 inches and 1.040 inches
Overall Width:
Between 1.020 inches and 1.040 inches
Mounting Slot Width:
Between 0.122 inches and 0.136 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
0.772 inches
Vibration Resistance Range In Hertz:
+10.0/+500.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.772 inches
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
Average Life Rating In Hours:
500.0
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference50.0 ohms 2nd radio interference50.0 ohms 3rd radio interference50.0 ohms 4th radio interference50.0 ohms 5th radio interference50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference50.0 ohms 2nd radio interference50.0 ohms 3rd radio interference50.0 ohms 4th radio interference50.0 ohms 5th radio interference50.0 ohms 6th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference400.0 2nd radio interference400.0 3rd radio interference400.0 4th radio interference400.0 5th radio interference400.0 6th radio interference
Operating Current Rating Per Function In Amps:
5.0 1st radio interference5.0 2nd radio interference5.0 3rd radio interference5.0 4th radio interference5.0 5th radio interference5.0 6th radio interference
Maximum Voltage Drop Per Function:
1.25 volts ac 1st radio interference and 2.0 volts dc 1st radio interference1.25 volts ac 2nd radio interference and 2.0 volts dc 2nd radio interference1.25 volts ac 3rd radio interference and 2.0 volts dc 3rd radio interference1.25 volts ac 4th radio interference and 2.0 volts dc 4th radio interference1.25 volts ac 5th radio interference and 2.0 volts dc 5th radio interference1.25 volts ac 6th radio interference and 2.0 volts dc 6th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference inductance-capacitance 2nd radio interference inductance-capacitance 3rd radio interference inductance-capacitance 4th radio interference inductance-capacitance 5th radio interference inductance-capacitance 6th radio interference
Input Terminal Manufacturer Code:
73030
Input Terminal Identification:
Sma connector plug
Output Terminal Manufacturer Code:
73030
Output Terminal Identification:
Sma-receptacle
Maximum Tempurature Rise:
25.0 degrees celsius
Full Load Insertion Loss Frequencies In Megahertz:
0.0 and 0.1 and 1.0 and 10.0 and 100.0 and 1000.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
2.5 and 2.5 and 2.5 and 17.0 and 40.0 and 40.0
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 slot
Features Provided:
Moisture resistant and shock resistant
Functional Terminal Type And Quantity:
6 friction w/grounding strap and pin input-output
Operating Voltage Rating And Type Per Function:
125.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function125.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function125.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function125.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function125.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function125.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function
Maximum Dielectric Withstanding Dc Voltage:
500.0 volts at sea level
Body Surface Treatment:
Cadmium
Criticality Code Justification:
Feat
Precious Material And Location:
Contact surfaces gold
Style Designator:
Filter connector
Item Name:
Filter,stop,radio Frequency
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC