Product Technical Spec.
Overall Length:
2.562 inches
Overall Height:
1.213 inches
Operating Tempurature Range:
-65.0/+160.0 degrees fahrenheit
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Operating Current Rating Per Function In Amps:
0.1 5th radio interference
Operating Current Rating Per Function In Amps:
0.3 3rd radio interference
Operating Current Rating Per Function In Amps:
0.6 4th radio interference
Operating Current Rating Per Function In Amps:
0.6 6th radio interference
Operating Current Rating Per Function In Amps:
3.0 1st radio interference
Operating Current Rating Per Function In Amps:
3.0 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
Mounting Facility Screw Thread Series Designator:
Unc
Inclosure Type:
Hermetically sealed
Operating Voltage Rating And Type Per Function:
20.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
20.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
20.0 volts dc 6th radio interference 6th function
Operating Voltage Rating And Type Per Function:
29.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
29.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
29.0 volts dc 3rd radio interference 3rd function
Thread Size:
0.086 inches
Maximum Dielectric Withstanding Dc Voltage:
250.0 volts at sea level
Item Name:
Magneto Filter Assembly
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC