Product Features
23 functions
Technical Specifications of NSN
Overall Length:
3.975 inches
Body Length:
3.000 inches
Body Height:
1.547 inches
Vibration Resistance Range In Hertz:
+10.0/+2000.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
4.460 inches
Operating Tempurature Range:
-55.0/+105.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Operating Current Rating Per Function In Amps:
0.025 3rd radio interference
Operating Current Rating Per Function In Amps:
0.025 4th radio interference
Operating Current Rating Per Function In Amps:
0.025 5th radio interference
Operating Current Rating Per Function In Amps:
0.025 6th radio interference
Operating Current Rating Per Function In Amps:
0.7 1st radio interference
Operating Current Rating Per Function In Amps:
0.7 2nd radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 2nd radio interference
Maximum Voltage Drop Per Function:
1.0 volts ac 1st radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts dc 3rd radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts dc 4th radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts dc 5th radio interference
Maximum Voltage Drop Per Function:
100.0 millivolts dc 6th radio interference
Mounting Facility Type And Quantity:
2 threaded hole
Mounting Facility Type And Quantity:
3 threaded stud
Functional Terminal Type And Quantity:
1 tab, solder lug ground 3rd function
Functional Terminal Type And Quantity:
23 turret input 1st function
Functional Terminal Type And Quantity:
23 turret output 2nd function
Operating Voltage Rating And Type Per Function:
200.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
200.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
25.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
25.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
25.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
50.0 volts dc 6th radio interference 6th function
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Filter,radio Interference
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC