Product Features
Thirty-three filtered functions; four grounded contacts
Technical Specifications of NSN
Overall Length:
2.012 inches
Overall Height:
1.219 inches
Overall Width:
1.219 inches
Unthreaded Mounting Hole Diameter:
Between 0.126 inches and 0.132 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
0.969 inches
Vibration Resistance Range In Hertz:
+10.0/+500.0
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
0.969 inches
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 6th radio interference
Operating Current Rating Per Function In Amps:
5.0 1st radio interference
Operating Current Rating Per Function In Amps:
5.0 4th radio interference
Operating Current Rating Per Function In Amps:
5.0 5th radio interference
Operating Current Rating Per Function In Amps:
5.0 6th radio interference
Operating Current Rating Per Function In Amps:
5.0 2nd radio interference
Operating Current Rating Per Function In Amps:
5.0 3rd radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 2nd radio interference and 2.0 volts dc 2nd radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 3rd radio interference and 2.0 volts dc 3rd radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 1st radio interference and 2.0 volts dc 1st radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 4th radio interference and 2.0 volts dc 4th radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 5th radio interference and 2.0 volts dc 5th radio interference
Maximum Voltage Drop Per Function:
1.2 volts ac 6th radio interference and 2.0 volts dc 6th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 5th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 6th radio interference
Input Terminal Manufacturer Code:
71468
Input Terminal Identification:
Mil-c-38999
Output Terminal Manufacturer Code:
71468
Output Terminal Identification:
Mil-c-38999
Maximum Tempurature Rise:
25.0 degrees celsius
Full Load Insertion Loss Frequencies In Megahertz:
0.1 and 1.0 and 10.0 and 100.0 and 500.0 and 1000.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels:
2.0 and 10.0 and 40.0 and 75.0 and 90.0 and 90.0
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 unthreaded hole
Features Provided:
Moisture resistant and shock resistant
Functional Terminal Type And Quantity:
37 friction w/grounding strap and pin input-output
Maximum Dielectric Withstanding Ac Rms Voltage:
300.0 volts at sea level
Operating Voltage Rating And Type Per Function:
120.0 volts ac 1st radio interference 1st function and 200.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 3rd radio interference 3rd function and 200.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 4th radio interference 4th function and 200.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 2nd radio interference 2nd function and 200.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 5th radio interference 5th function and 200.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
120.0 volts ac 6th radio interference 6th function and 200.0 volts dc 6th radio interference 6th function
Maximum Dielectric Withstanding Dc Voltage:
300.0 volts at sea level
Body Surface Treatment:
Cadmium
Precious Material And Location:
Contact surfaces gold
Style Designator:
Filter connector
Item Name:
Filter,power Line
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC