#LMF1288 Noise Filter | Filters And Networks

LMF1288

Radio Frequency Interfere Filter

NSN 5915-00-166-8166

DEMIL
Shelf Life
UOM
NIIN
Demil:
DEMIL/MLI
Shelf Life:
N/A
UOM:
1 EA
NIIN:
001668166

Product Technical Spec.

Overall Height:
2.250 inches
Body Length:
Between 6.220 inches and 6.280 inches
Body Width:
Between 1.440 inches and 1.500 inches
Body Height:
Between 1.770 inches and 1.830 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
Between 5.820 inches and 5.840 inches
Vibration Resistance Range In Hertz:
+10.0/+2000.0
Vibration Resistance Range In Hertz:
+10.0 to 2000.0
Operating Tempurature Range:
-55.0/+95.0 degrees celsius
Operating Tempurature Range:
-55.0 to 95.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference 1st function
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference 4th function
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference 2nd function
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference 1st function
Load Impedance Per Function:
50.0 ohms 2nd radio interference 2nd function
Load Impedance Per Function:
50.0 ohms 3rd radio interference 3rd function
Load Impedance Per Function:
50.0 ohms 4th radio interference 4th function
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz:
400.0 1st radio interference 1st function
Power Line Frequency Rating Per Function In Hertz:
400.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference
Operating Current Rating Per Function In Amps:
1.5 3rd radio interference
Operating Current Rating Per Function In Amps:
1.5 4th radio interference
Operating Current Rating Per Function In Amps:
2.5 1st radio interference
Operating Current Rating Per Function In Amps:
1.0 2nd radio interference 2nd function
Operating Current Rating Per Function In Amps:
1.5 4th radio interference 4th function
Operating Current Rating Per Function In Amps:
2.5 1st radio interference 1st function
Maximum Voltage Drop Per Function:
400.0 millivolts ac 2nd radio interference
Maximum Voltage Drop Per Function:
750.0 millivolts ac 1st radio interference
Maximum Voltage Drop Per Function:
750.0 millivolts dc 3rd radio interference
Maximum Voltage Drop Per Function:
750.0 millivolts dc 4th radio interference
Maximum Voltage Drop Per Function:
750.0 millivolts dc 3rd radio interference 3rd function
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 2nd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 3rd radio interference
Principal Circuitry Type Per Function:
Inductance-capacitance 1st radio interference 1st function
Principal Circuitry Type Per Function:
Inductance-capacitance 4th radio interference 4th function
Mounting Facility Screw Thread Series Designator:
Unc
Inclosure Type:
Encased
Mounting Facility Type And Quantity:
2 threaded hole
Functional Terminal Type And Quantity:
4 tab, solder lug output 2nd function
Functional Terminal Type And Quantity:
5 tab, solder lug input 1st function
Functional Terminal Type And Quantity:
7 turret ground 3rd function
Operating Voltage Rating And Type Per Function:
26.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
28.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 1st radio interference 1st function
Thread Size:
0.138 inches
Maximum Dielectric Withstanding Dc Voltage:
322.0 volts at sea level
Style Designator:
Rectangular terminal/terminals on one surface
NSN:
5915-00-166-8166
Item Name:
Filter,noise
Cage Code:
29098

Cross Referenced Parts

Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC
Part Number:
RF09287
Cage Code:
13619
RNCC:
C
RNVC:
1
RNAAC:
ZZ
Status:
A
MSDS:
SADC:
9X
Part Number:
63-010
Cage Code:
32155
RNCC:
3
RNVC:
2
RNAAC:
KE
Status:
A
MSDS:
SADC:
Part Number:
573A94
Cage Code:
94033
RNCC:
5
RNVC:
2
RNAAC:
KE
Status:
A
MSDS:
SADC:
Part Number:
8833300002-1
Cage Code:
57057
RNCC:
7
RNVC:
2
RNAAC:
KE
Status:
A
MSDS:
SADC:
Part Number:
RF9287
Cage Code:
13619
RNCC:
5
RNVC:
9
RNAAC:
ZZ
Status:
A
MSDS:
SADC:

  We Guarantee with Every Order

  •   100% Genuine Manufacturers Parts
  •   Every Product thoroughly Inspected
  •   Sales Record Retention of 7 years
  •   Fast Delivery
  •   HAZMAT Certified
  •   Global Shipping

Pricing & Availability

Submit this form for current pricing and availability quote on part number lmf1288 and/or cross reference parts.
Part / NSN:
Qty:
Your Email:
Phone:
Ref. / PO #:
Company:

We do not share or sell your information to anyone.
Privacy | Terms

Catalog Drilldown
--- Electrical And Electronic Equipment Components
------ Filters And Networks
--------- Radio Frequency Interfere Filters
------------ P/N LMF1288

Best-Selling Products A collection of our most popular products

Last Updated: 12/26/2024