Product Technical Spec.
Overall Height:
2.312 inches
Body Length:
4.380 inches
Body Height:
2.000 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
3.875 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width:
1.500 inches
Operating Tempurature Range:
-55.0/+125.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 5th radio interference
Source Impedance Rating Per Function:
50.0 ohms 6th radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 6th radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 5th radio interference
Operating Current Rating Per Function In Amps:
0.1 5th radio interference
Operating Current Rating Per Function In Amps:
0.2 1st radio interference
Operating Current Rating Per Function In Amps:
0.12 6th radio interference
Operating Current Rating Per Function In Amps:
0.2 2nd radio interference
Operating Current Rating Per Function In Amps:
0.2 3rd radio interference
Operating Current Rating Per Function In Amps:
0.45 4th radio interference
Mounting Facility Screw Thread Series Designator:
Unc
Inclosure Type:
Hermetically sealed
Mounting Facility Type And Quantity:
4 threaded hole
Functional Terminal Type And Quantity:
3 connector, receptacle input-output 2nd function
Functional Terminal Type And Quantity:
4 threaded stud input 1st function
Operating Voltage Rating And Type Per Function:
25.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
25.0 volts dc 5th radio interference 5th function
Operating Voltage Rating And Type Per Function:
25.0 volts dc 6th radio interference 6th function
Operating Voltage Rating And Type Per Function:
26.0 volts ac 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function:
40.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
115.0 volts ac 3rd radio interference 3rd function
Thread Size:
0.138 inches
Body Surface Treatment:
Tin
Cross Referenced Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC